Flow Measurement Methods Apparatus
Description
Brand: Tecquipment
Model: H10
Country of Origin: United Kingdom
Manufacturer: United Kingdom
Features:
- Should show the typical methods of measuring the flow of an essentially incompressible fluid (water)
- It also should show applications of Bernoulli’s equation
- Students should be able to measure flow using a Venturi meter, an orifice plate meter and a rotameter
- Bernoulli’s equation should work for each meter
- Losses in a rapid enlargement and a 90-degree elbow to be found
- It should have a horizontal pipe that include a Venturi meter, orifice plate and pressure tappings
- An elbow should connect the pipe to a rotameter (gap-type flow meter) with further pressure tappings
- All pressure tappings should connect to manometers held on a vertical panel behind the pipe work
- The manometers should measure and show pressure distribution against a calibrated scale
- Water from a digital hydraulic bench should flow through the Venturi meter, through a sudden enlargement, a settling length and the orifice plate
- It then should flow around the elbow, through the rotameter, then a flow control valve, finally returning to the hydraulic bench
- The control valve should be downstream
- To adjust the datum water level in the manometer tubes, a hand-pump to be connected (should be included) to the valve above the manometer tubes
Experimental Capabilities:
- Application of the Bernoulli equation for incompressible fluids
- Direct comparison of flow measurement using a Venturi meter, orifice plate and rotameter
- Comparison of pressure drops across each flow measurement device
- Comparison of pressure drops across a sudden enlargement and a 90° elbow
Technical Parameters:
- Orifice plate: Minimum 20 mm diameter with corner tappings, manufactured to BS1042
- Sudden enlargement: 26 mm to 51.9 mm
- Rotameter: Scaled 0 to 210 mm. Should include calibration chart for 0 to 35 litres per minute
- Drawing & dimensions of Venturi meter and Orifice meter should be silk-screened on to base plate
- Venturi:
- Material: Clear Acrylic
- Upstream diameter: 26 mm ± 0.05 m
- Throat diameter: 16 mm ± 0.02 mm
- Downstream diameter: 26 mm ± 0.05 mm
- Upstream taper: 22.6°
- Downstream taper: 6.4°
- Coefficient of Discharge: Nominally 0.93
- Minimum 11 Manometer tubes
- Manometer should be scaled to 0 to 380 mm
- Maximum flow: 28 litres per minute
- Should be supplied with all necessary pipe clips, tubing and printed operation manual
Hydraulics Data Management System Software:
- Simple software tool for manual data entry and recording of data for hydraulics experiments
- Intuitive and easy-to-use, with clear, customisable display and layout options
- Automatic calculation, charting and data export for efficient use of students? and lecturers? Time
- Recording data manually
- Display of data in digital form or as an analogue meter
- Logging of data for printing and later analysis
- Export of data to Exce
- Perform calculations of recorded data
- Create charts with live updates as data is entered
Reviews