Electrical Wiring Trainer Board (Component & Sequence)
Description
Brand: PValley
Model: CPS-3100B
Country of Origin: China
Manufacturer: Bangladesh
General Specification:
Body Material:
Printed Front Side Sheet
Sheet Type: Digital
Country of origin: China
Feature:
- Sheet number 26
- Storage Printed temperature 300°c
- Color White/Silver
Hard Plastic Sheet
Sheet Type: Digital
Country of origin: Pakistan
Feature:
- Sheet thickness 10mm
- Two-Part Combination (Transparent/white)
- UV Printout
Safety Breaker
Brand: Hyundai
Country of origin: South Korea
Feature:
Protection System
Brand: Hyundai
Country of origin: South Korea
Feature:
- Safety tripping
- Low insertion loss and high reliability
- Human Body Sense safety
- Current error detection range is 20mA
- Soft tripping
- Low noise cut off
Panel Box
Brand: Madhav Enterprise
Country of origin: Indian
Features:
- Shape: Rectangular
- Surface Finish: Smooth
- High quality raw material
Best structure
Brand: Altech
Country of origin: Bangladesh
Feature:
- Sheet thickness 5mm
- Sheet (Silver/white)
- Square Shape
Power Monitoring
Brand: UNI-T
Country of origin: China
Feature:
- Self-operating voltage 12V
- Self-Consumption Current 20mA
- Power Nature
Use Connector
Brand: ZHT
Country of origin: China
Feature:
- Banana Female Connector Diameter 13mm
- Banana Male Connector Diameter 4.5mm
Working area:
- Working area: 30 * 24 inch
Technical Specifications:
- Provide available electrical components and interconnect in different configurations,
- Acquire the basic knowledge on electrical engineering, installations and electrical measurements.
- Study the means to check the main laws and principles.
- Component symbols and electrical diagrams are represented on the front panel.
- The symbols and electrical diagrams of each component are clearly represented on the front panel.
- The connections are eased by 4mm terminals and cables of different colors.
- The power supplies are included with extra low safety voltage.
- General switch, fuse and signaling lamp:
- 1 Safety single-phase transformer 115-230V/6-12-24 VAC-JA
- 2 Fuse-holder with fuse type 6×30-1A
- 1 Moving iron ammeter with range 0.5-1A
- 1 Moving iron voltmeter with range: 25 V
- 10 Resistors of different values (2.4.8.16.31.5.63.250, 500, 1000,2000)
- 1 linear rheostat 100/25W
- 4 Diodes 6A-100V
- 2 Lamp-holder with 24-V signaling lamp
- 24-Vac buzzer
- 1 Electrolytic capacitor, 100 F25Vde
- 2 Electrolytic capacitors, 500 F25Vde
- 2 Inductances 60 ml 0.5 A
Electrical Sequence Trainer:
- Hands-on electrical sequence practices using various electrical components with electric contact.
- Simulates real life components and power source that is being used in the field
- Ensures safety using insulated connection cables and insulated connection terminals
Experimental Contents:
- Basic circuit
- Logic circuit
- Self-holding circuit
- Timer circuit
- Priority circuit
- Detection circuit
- Lamp and alarm circuit
- Motor operational circuit
- Reactor-driving circuit
- Jog circuit
- Forward & reverse circuit
- Delay operation circuit
- Time activation circuit
- Y-A operational circuit
Earth leakage circuit breaker (ELCB): I ea
- Rated voltage: AC 220V 60Hz
- Rated current: 30A
- Rated residual current: 30mA
Electronic contactor (5a2b): 3ea
- Contact capacity: AC 240V/180/4.5kW
- Auxiliary contact capacity: AC 240V 3A
Electronic overload relay (EOCR, 1/2HP): 1 ea
- Internal CT (sensor): 3-CT (tunnel type)
- Current setting: 0.3-1.5A
- Trip time setting: 0-30 sec.
- Contact capacity: AC 250V 3A (Resistive load)
Relay (4C): 1ea
- Contact capacity: AC 220V 3A (Resistive load)
Timer (30 seconds): lea
- Operational method: ON delay
- Output contact capacity: AC 220V 1.5A (Resistive load)
Flicker timer (6 seconds): lea
- Operational method: ON Start
- Output contact capacity: AC 220V 2.5A (Resistive loud)
3-phase induction motor: lea
- Operating voltage: 3-phase AC220V/380V/25W
- Type of motor: Squirrel cage rotor, 4-pole and Y-A Starting
- Rotary dise: Rotational speed detection type
- Electronic brake: Intensity control function
- Proximity sensor: lea
- Digital counter: lea
- DC power supply: lea Output: DC 24V IA (fuse)
- Lamp: deu
- Buzzer: I ea
- Push button: lea
- Toggle switch (lalb): 1eaFuse and fuse holder: Zea
- Supports angle adjustment: lea
- STANDARD ACCESSORIES:
- Power cord: lea
- 40 insulated connection cable: Iset
- User’s guide & experimental manual: Lea
Digital Multifunctional Meter:
- Showing electrical wiring tips on the LCD screen
- User-defined backlight setting (10/20/30 sec.)
- 2% precision
- Fast and accurate response rate
- Effective measurement of RMS values Indication of a measured data in the minimum, maximum and average values
- Earth resistance measurement in two points and three points
- Automatic Power OFF function
- Bluetooth communication.
- Displays the connection of reed wires
- AUTO/MANUAL range selection
- Initiation of calibration by pressing a key button
- ACV: 0.0-750.0V True RMS.
- DCV: 0.0-999.9V
- Insulation resistance (MEG 2):
- DC 1000V: 0,00ΜΩ -9,99ΜΩ, 10.00ΜΩ -99.99ΜΩ, 100.0ΜΩ-1999ΜΩ
- DC 500V: 0.00ΜΩ-9.99ΜΩ, 10.00ΜΩ – 99,99ΜΩ, 100.0ΜΩ – 999.9ΜΩ
- DC 250V: 0.00ΜΩ -9.99ΜΩ, 10.0042-99,99ΜΩ, 100.0ΜΩ~999.9ΜΩ
- Ground resistance (EAR 2): 0-20000
- Ground voltage (EV): 0.0-750.0V AC, True RM
- PHA: AC110V-750V LCD Display
- HOT: AC70V-750V Buzzer, LCD Display
- ACA: 0-9999A, True RMS
- lor: 0.00-9.99mA, True RMS
- Communication: Bluetooth 4.0
STANDARD ACCESSORIES:
- User’s guide manual
- SV Alkaline AA battery Sea
- Protective rubber cover (orange color)
- Carrying bag lea
- Test lead wire (red color, mega 2 and 1.2m roll length) len
- Test lead wire (black color. mega 2 and 1.2m roll length)- lea
- Test probe (red color, 600V and CAT III-lea
- Test probe (black color, 600V and CAT III)-lea
- Crocodile clip (black color, EN61010 and CAT III) lea
- Test lead wire green color, KSC3325and 1.2m roll length) lea
- Test lead wire (red color, 600V and 20m roll length) lea
- Test lead wire (yellow color, 600V and 10m roll length) lea
- Test lead wire (green color, 600V and 5m roll length) lea
- Ground rod-2ea
Accessories:
- Power Cord: 01 Set
- Connecting Wire & Cable
- User Manual or User Guide
- Complete 5 days Training Included
Protection:
Under voltage, Supply over voltage, Drive overload, Ground fault, etc.
Warranty: 1 (One) year with services
Reviews
There are no reviews yet.