Variable Frequency Drive (VFD) Training System
Description
Brand: PValley
Model: PH-2124S8
Country of Origin: Bangladesh
Features:
- Best type Printed Sheet
- Hard Round support board or Plastic Sheet
- Safety Breaker.
- Protection System
- Panel Box
- Best structure.
- Power Monitoring
- Use Connector
- Working area:
- Support System: Windows XP / Win 7 / Win 8 / Win 10 / Win 11/ Linux
- Working area: 22.86 *20.32*4 cm
- Frame size: 76.2 * 62.23 *4 cm Controller:
- Mains input Voltage: 1 Phase 220V to 3Phase/ 50/60Hz (380V / 415V – Selective)
- Power Range: 3.3KW
- Input Frequency 50/60Hz CPU Details:
- Adjustable Output frequency (90-1000) Hz
- Start/Stop Push Button
- Frequency Meter
- Exciter
- Analog Input 2 Way
- Digital Input 6 Way
- Analog Output 2 Way
- Digital Output 1Way
- Power Lamp
- AC & DC Voltmeter
- AC & DC Ampere meter
- Digital Speed meter
- Relay Output 2 way
- RS485 Communication Terminal Control:
- Open-loop vector control variable frequency drive
- Speed or torque control variable frequency drive
- Speed reference input: 0-10V, 0-20mA, 4-20mA, (-10 to +10V SM-I/O Lite option)
- 4 digital inputs- World (enable, run forward, run a reverse, local/remote)-(not stop, run, jog, local/remote)
- VFD switching frequency: 3 (default) – 6 – 12– 18 kHz
- VFD Output frequency 0 to 1500Hz
- VFD Accelerate and Decelerate ramps (linear and S type)
- Positive logic control
- Serial communication – Modbus RTU RS485 via RJ45 connector- Baud rate 4800, 9600, 19200or 38400 bits per second
- DC injection braking as standard in the VFD
- Dynamic braking transistor as standard in the VFD
- Dynamic motor flux V/Hz for energy saving
- Quadratic motor flux V/Hz for fan and pump optimization General Characteristics-
- VFD maximum overload 150% of rated current for the 60s
- Intelligent Thermal Management (ITM) optimizes switching frequency
- 8 preset speeds in the VFD
- Flying start
- Mains dip ride through
- Automatic no-spin auto-tune for fast performance optimization
- VFD’s keypad access to all parameters for more demanding parameter settings Environment-
- NEMA 1 rating with optional cover
- Ambient temperature – 10 to +40°C @ 3kHz switching
- Humidity 95% maximum (non-condensing)
- Electromagnetic Immunity complies with EN61800-3 and EN61000-6-3 and 4
- Electromagnetic Emissions comply with EN61800-3 (second environment) as standard. Complies with EN61000-6-3 (residential)and EN61000-6-4 (industrial) generic standards with optional footprint EMC filter.
Reviews
There are no reviews yet.