Variable Frequency Drive (VFD) Training System

Description

Brand: PValley

Model: PH-2124S8

Country of Origin: Bangladesh

Features:

  • Best type Printed Sheet
  • Hard Round support board or Plastic Sheet
  • Safety Breaker.
  • Protection System
  • Panel Box
  • Best structure.
  • Power Monitoring
  • Use Connector
  • Working area:
  • Support System: Windows XP / Win 7 / Win 8 / Win 10 / Win 11/ Linux
  • Working area: 22.86 *20.32*4 cm
  • Frame size: 76.2 * 62.23 *4 cm Controller:
  • Mains input Voltage: 1 Phase 220V to 3Phase/ 50/60Hz (380V / 415V – Selective)
  • Power Range: 3.3KW
  • Input Frequency 50/60Hz CPU Details:
  • Adjustable Output frequency (90-1000) Hz
  • Start/Stop Push Button
  • Frequency Meter
  • Exciter
  • Analog Input 2 Way
  • Digital Input 6 Way
  • Analog Output 2 Way
  • Digital Output 1Way
  • Power Lamp
  • AC & DC Voltmeter
  • AC & DC Ampere meter
  • Digital Speed meter
  • Relay Output 2 way
  • RS485 Communication Terminal Control:
  • Open-loop vector control variable frequency drive
  • Speed or torque control variable frequency drive
  • Speed reference input: 0-10V, 0-20mA, 4-20mA, (-10 to +10V SM-I/O Lite option)
  • 4 digital inputs- World (enable, run forward, run a reverse, local/remote)-(not stop, run, jog, local/remote)
  • VFD switching frequency: 3 (default) – 6 – 12– 18 kHz
  • VFD Output frequency 0 to 1500Hz
  • VFD Accelerate and Decelerate ramps (linear and S type)
  • Positive logic control
  • Serial communication – Modbus RTU RS485 via RJ45 connector- Baud rate 4800, 9600, 19200or 38400 bits per second
  • DC injection braking as standard in the VFD
  • Dynamic braking transistor as standard in the VFD
  • Dynamic motor flux V/Hz for energy saving
  • Quadratic motor flux V/Hz for fan and pump optimization General Characteristics-
  • VFD maximum overload 150% of rated current for the 60s
  • Intelligent Thermal Management (ITM) optimizes switching frequency
  • 8 preset speeds in the VFD
  • Flying start
  • Mains dip ride through
  • Automatic no-spin auto-tune for fast performance optimization
  • VFD’s keypad access to all parameters for more demanding parameter settings Environment-
  • NEMA 1 rating with optional cover
  • Ambient temperature – 10 to +40°C @ 3kHz switching
  • Humidity 95% maximum (non-condensing)
  • Electromagnetic Immunity complies with EN61800-3 and EN61000-6-3 and 4
  • Electromagnetic Emissions comply with EN61800-3 (second environment) as standard. Complies with EN61000-6-3 (residential)and EN61000-6-4 (industrial) generic standards with optional footprint EMC filter.

Reviews

There are no reviews yet.

Be the first to review “Variable Frequency Drive (VFD) Training System”

Your email address will not be published. Required fields are marked *